Legislation Details

File #: 26-6287    Version: 1
Type: Administrative Memorandum Status: Agenda Ready
File created: 8/12/2026 In control: Board of Directors
On agenda: 8/27/2026 Final action:
Title: Texoma Raw Water Pipeline No. 2 and Texoma Raw Water Pipeline to Leonard Water Treatment Plant (WTP) Pipeline; Project No. 101-0633-23 and No. 101-0642-24; Guaranteed Maximum Price; Work Authorization Nos. 1 and 2; Engineering Services During Construction; and Owner Advisor Services During Construction
Indexes: .RWS - Regional Water System, Construction Manager At-Risk, Construction Manager At-Risk - Guaranteed Maximum Price, Engineering Services During Construction , Owner Advisor Agreement
Code sections: 101-0633-23 - Texoma Raw Water Pipeline No 2 , 101-0642-24 - Texoma Raw Water Pipeline to Leonard WTP Pipeline
Attachments: 1. Map
Date Ver.Action ByActionResultAction DetailsMeeting DetailsVideo
No records to display.
Regional Water System

title
Texoma Raw Water Pipeline No. 2 and Texoma Raw Water Pipeline to Leonard Water Treatment Plant (WTP) Pipeline; Project No. 101-0633-23 and No. 101-0642-24; Guaranteed Maximum Price; Work Authorization Nos. 1 and 2; Engineering Services During Construction; and Owner Advisor Services During Construction

end
SUBJECT

recommendation
Authorize execution of an amendment to a Construction Manager At-Risk (CMAR) agreement with Garney Companies, Inc for a Guaranteed Maximum Price (GMP) amount of $538,548,359.96 for the Texoma Raw Water Pipeline No. 2 and Texoma Raw Water Pipeline to Leonard Water Treatment Plant (WTP) Pipeline; funding for Work Authorization No. 1 in the amount of $155,690,889.88; funding for Work Authorization No. 2 in the amount of $196,826,974.87; funding to Black & Veatch Corporation in the amount of $2,458,012.00 for Engineering Services During Construction; funding to Freese and Nichols, Inc. in the amount of $1,211,835.00 for Engineering Services During Construction; and funding to Plummer Associates, Inc. in the amount of $15,813,500.00 for Owner Advisor Services during Construction.
end

PURPOSE

The Texoma Raw Water Pipeline No. 2 will parallel the existing Texoma Raw Water Pipeline and provide additional capacity to NTMWD's water transmission system from the Lake Texoma Pump Station to the water treatment facilities in Wylie and Leonard. The Texoma Raw Water Pipeline to Leonard Water Treatment Plant (WTP) Pipeline will divert raw water from Lake Texoma to the Leonard WTP for blending with Bois d'Arc Lake water. The CMAR has submitted the GMP for the Texoma Raw Water Pipeline No. 2 and Texoma Raw Water Pipeline to Leonard Water Treatment Plant (WTP) Pipeline projects.

RECOMMENDATION

The Executive Director and NTMWD staff recommend the Board of Directors authorize the Executive Director to execute an amendment to the CMAR agreement for a GMP and execute Work Authorization Nos. 1 and 2 to the CMAR, Engineerin...

Click here for full text